Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Rev Bras Epidemiol ; 25(Supl 2): e220013, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36327418

RESUMO

OBJECTIVE: To evaluate changes in selected laboratory tests in the population included in the Brumadinho Health Project, according to the exposure to the dam failure. METHODS: Cross-sectional study carried out on representative sample of residents (≥12 years) in Brumadinho, Minas Gerais, including: 1) non-exposed; 2) directly affected by tailings sludge; 3) residents in mining area. The prevalence of abnormal results of blood count, total, HDL and LDL cholesterol, triglycerides, aspartate aminotransferase, alanine aminotransferase, creatinine, urea, estimate of glomerular filtration rate (eGFR) and high-sensitivity C-reactive protein (hs-CRP) were estimated. The Prevalence Ratios (PR) and 95% Confidence Intervals (95%CI) of having an abnormal laboratory finding were estimated using Generalized Linear Models with Poisson probability distribution. Crude and adjusted models were estimated for age range, gender, diabetes, body mass index, smoking, hypertension. RESULTS: After adjusting, there was no difference in PR between the three populations for most tests, with the exception of the population residing in an area with mining activity and not directly affected by the mud, with a lower chance of having altered total cholesterol (PR: 0.84; 95%CI 0.74-0.95) and a higher chance of having altered HDL cholesterol (PR: 1.26; 95%CI 1.07-1.50), hs-CRP (PR: 1.19; 95%CI 1.04-1.37), and eGFR <60mL/min/1,73 m2 (PR: 1.51; 95%CI 1.05-2.19). CONCLUSION: No significant differences were found in the prevalence of biochemical and hematological alterations between the populations directly exposed and not exposed to tailings. Only the group residing in the mining area had a higher prevalence of alterations related dyslipidemia, renal disease, and inflammation.


Assuntos
Proteína C-Reativa , Humanos , Proteína C-Reativa/análise , Proteína C-Reativa/metabolismo , Estudos Transversais , Brasil/epidemiologia , HDL-Colesterol , LDL-Colesterol , Fatores de Risco
2.
Adv Rheumatol ; 62: 34, 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403088

RESUMO

Abstract Background: The VI Brazilian Consensus on Autoantibodies against HEp-2 cells for determination of autoantibodies against cellular constituents on HEp-2 cells was held on September, 2019, in Fortaleza (CE, Brazil). The guidelines in this edition were formulated by the group of Brazilian experts discussing the classification of complex patterns, the classification of the nuclear discrete dots (few and multiple), the identification of the discrete fine speckled pattern (AC-4a) and improvements on the ANA report. Mainbody: Sixteen Brazilian researchers and experts from universities and clinical laboratories representing the various geographical regions of Brazil participated in the meeting. Four main topics were discussed: (1) How to classify patterns with fluorescence in more than one cell compartment considering three relevant categoris: composite patterns, mixed patterns and multiple patterns; (2) The splitting of the discrete nuclear dots pattern into the multiple discrete nuclear dots (AC-6) and few discrete nuclear dots (AC-7) patterns, respectively; (3) Inclusion of a novel nuclear pattern characterized by discrete fine speckled pattern highly associated with antibodies to SS-A/Ro60, classified as AC-4a. In addition, adjustments on the Brazilian Consensus nomenclature were implemented aiming to harmonize the designation of some patterns with the International Consensus on ANA Patterns (ICAP). Furthermore, the designations of the PCNA-like pattern (AC-13), CENP-F-like pattern (AC-14) and Topo I-like pattern (AC-29) were adjusted in accordance to ICAP. Finally, there was a recommendation for adjustment in the test report in order to address the status of nuclear envelope staining. For all topics, the aim was to establish specific guidelines for laboratories and clinicians. All recommendations were based on consensus among participants. All recommendations from the V Consensus were maintained and there was relevant progress in the BCA/HEp-2 guidelines and further harmonization with ICAP. Conclusion: The VI BCA/HEp-2 edition was successful in establishing important recommendations regarding the classification of complex patterns, in supporting the identification of a novel pattern within the AC-4 group and in the harmonization process with the ICAP terminology.

3.
Rev. bras. epidemiol ; 25(supl.2): e220013, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1407532

RESUMO

ABSTRACT Objective: To evaluate changes in selected laboratory tests in the population included in the Brumadinho Health Project, according to the exposure to the dam failure. Methods: Cross-sectional study carried out on representative sample of residents (≥12 years) in Brumadinho, Minas Gerais, including: 1) non-exposed; 2) directly affected by tailings sludge; 3) residents in mining area. The prevalence of abnormal results of blood count, total, HDL and LDL cholesterol, triglycerides, aspartate aminotransferase, alanine aminotransferase, creatinine, urea, estimate of glomerular filtration rate (eGFR) and high-sensitivity C-reactive protein (hs-CRP) were estimated. The Prevalence Ratios (PR) and 95% Confidence Intervals (95%CI) of having an abnormal laboratory finding were estimated using Generalized Linear Models with Poisson probability distribution. Crude and adjusted models were estimated for age range, gender, diabetes, body mass index, smoking, hypertension. Results: After adjusting, there was no difference in PR between the three populations for most tests, with the exception of the population residing in an area with mining activity and not directly affected by the mud, with a lower chance of having altered total cholesterol (PR: 0.84; 95%CI 0.74-0.95) and a higher chance of having altered HDL cholesterol (PR: 1.26; 95%CI 1.07-1.50), hs-CRP (PR: 1.19; 95%CI 1.04-1.37), and eGFR <60mL/min/1,73 m2 (PR: 1.51; 95%CI 1.05-2.19). Conclusion: No significant differences were found in the prevalence of biochemical and hematological alterations between the populations directly exposed and not exposed to tailings. Only the group residing in the mining area had a higher prevalence of alterations related dyslipidemia, renal disease, and inflammation.


RESUMO Objetivo: Avaliar alterações em parâmetros laboratoriais na população do Projeto Saúde Brumadinho, segundo exposição ao rompimento da barragem. Métodos: Estudo transversal realizado em amostra representativa de residentes (≥12 anos) em Brumadinho, Minas Gerais, incluindo: não expostos (grupo referência); diretamente atingidos pela lama de rejeitos; e residentes em área de mineração. Foram estimadas as prevalências de resultados alterados de hemograma, colesterol total, colesterol lipoproteína de alta densidade (HDL), colesterol lipoproteína de baixa densidade (LDL), triglicérides, aspartato aminotransferase, alanina aminotransferase, creatinina, ureia, estimativa da taxa de filtração glomerular (TFGe) e proteína C-reativa ultrassensível (PCRus). As razões de prevalência (RP) e os intervalos de confiança de 95% (IC95%) de ter o exame alterado foram estimados por meio de modelos lineares generalizados com distribuição de probabilidade Poisson. Estimaram-se modelos brutos e ajustados por faixa etária, sexo, diabetes, índice de massa corporal, tabagismo, hipertensão. Resultados: Após ajustes, não se observou diferença nas RP entre as populações estudadas para a maioria dos testes, com exceção da população residente em área com atividade de mineração e não diretamente atingida pela lama, com menor chance de ter colesterol total alterado (RP=0,84; IC95% 0,74-0,95) e maior chance de ter colesterol HDL (RP=1,26; IC95% 1,07-1,50) e PCRus (RP=1,19; IC95% 1,04-1,37) alterado e TFGe<60 mL/min/1,73 m2 (RP=1,51; IC95% 1,05-2,19). Conclusão: Não foram encontradas diferenças significativas na prevalência de alterações bioquímicas e hematológicas entre a população diretamente exposta aos rejeitos e a população não exposta. Apenas o grupo residente em área de mineração apresentou maior prevalência de alterações relacionadas com dislipidemia, disfunção renal e inflamação.

4.
Adv Rheumatol ; 59: 28, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1088624

RESUMO

Abstract Background: The V Brazilian Consensus for determination of autoantibodies against cellular constituents on HEp-2 cells, held in Brasilia (DF, Brazil) on August 27, 2016, discussed the harmonization between the Brazilian Consensus on ANA (BCA) guidelines and the International Consensus on ANA Patterns (ICAP) recommendations (www.anapatterns.org). Initial guidelines were formulated by the group of Brazilian experts with the purpose of guiding and enabling Brazilian clinical laboratories to adopt recommendations and to provide a common standard for national and international consensuses. Mainbody: Twenty Brazilian researchers and experts from universities and clinical laboratories representing the various geographical regions of the country participated in the meeting. Three main topics were discussed, namely the harmonization between the BCA guidelines and latest recommendations of the ICAP initiative, the adjustment of the terminology and report on HEp-2 patterns, and a reassessment of quality assurance parameters. For the three topics, our aim was to establish specific guidelines. All recommendations were based on consensus among participants. There was concrete progress in the adjustment of the BCA guidelines to match the ICAP guidelines. To a certain extent, this derives from the fact that ICAP recommendations were largely based on the algorithm and recommendations of the IV Brazilian ANA Consensus, as consistently recognized in the ICAP publications and presentations. However, although there is great overlap between the two Consensuses, there are some point divergences. These specific items were individually and extensively discussed, and it was acknowledged that in several points ICAP improved recommendations previously issued by the Brazilian ANA Consensus and these changes were readily implemented. Regarding some specific topics, the BCA panel of experts felt that the previously issued recommendations remained relevant and possibly will require further discussion with ICAP. The term anti-cell antibodies was adopted as the recommended designation, recognizing that the assay addresses antibodies against antigens in the nucleus and in other cell compartments. However, the acronym ANA HEp-2 was maintained due to historical and regulatory reasons. It was also signalized that the latest trend in ICAP is to adopt the term Indirect Immunofluorescent Assay on HEp-2 cell substrate (HEp-2 IIFA). In addition, the quality assurance strategies previously presented were ratified and emphasized. Conclusion: The V BCA edition was successful in establishing an overall harmonization with the ICAP recommendations for interpretation of the HEp-2 IIFA test, pinpointing the perspectives in filling the remaining gaps between both initiatives.


Assuntos
Autoanticorpos/análise , Células Hep G2 , Anticorpos Antinucleares , Guias como Assunto/normas , Técnica Indireta de Fluorescência para Anticorpo/instrumentação
5.
Rev Bras Reumatol ; 54(1): 13-20, 2014.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24878786

RESUMO

OBJECTIVE: To establish the abnormal title and the appropriate screening dilution for ANA (antinuclear antibodies) test by indirect immunofluorescence on HEp-2 cells (ANA HEp-2). METHODS: An analysis of ANA Hep-2 in serum samples from 126 healthy individuals was performed. The samples were screened at a dilution of 1:80, and those positive were diluted to the title of 1:5120. The abnormal title of ANA was defined as that corresponding to the 95th percentile of the test in this population. The sensitivity of the different titles of antinuclear antibodies was determined in a group of 136 patients with a diagnosis of autoimmune rheumatic disease, and the specificity was determined in a group of 118 patients with other rheumatic diseases. The optimal cutoff value of the test was determined by ROC curve analysis. RESULTS: The frequency of ANA positivity in healthy subjects was 13.2%. There was no difference in the frequency of positive results according to gender or age. The abnormal title of ANA was defined as the dilution of 1:160. The 1:80 dilution had sensitivity of 87.7% and specificity of 67.8%, while the 1:160 dilution had sensitivity of 82% and specificity of 73.7%. By ROC curve analysis, a dilution of 1:160 corresponded to the optimal cutoff value. CONCLUSION: The abnormal title and the optimal cutoff value of ANA HEp-2 in the population was 1:160. Therefore, the dilution of 1:160 is the optimal screening dilution, with better specificity but without significantly compromising the sensitivity of the diagnostic test.


Assuntos
Anticorpos Antinucleares/sangue , Anticorpos Antinucleares/isolamento & purificação , Doenças Autoimunes/sangue , Doenças Autoimunes/diagnóstico , Doenças Reumáticas/sangue , Doenças Reumáticas/diagnóstico , Adulto , Doenças Autoimunes/imunologia , Linhagem Celular Tumoral , Células Epiteliais/classificação , Células Epiteliais/imunologia , Feminino , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Doenças Reumáticas/imunologia
6.
Rev Bras Reumatol ; 54(1): 44-50, 2014.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24878791

RESUMO

OBJECTIVE: The Fourth Brazilian Consensus for Autoantibodies Screening in HEp-2 Cells (ANA) was held in Vitória, Espírito Santo, and aimed to discuss strategies and recommendations about the technique, standardization, interpretation and quality control of the indirect immunofluorescence reaction on HEp-2 cells. METHODS: Twenty three ANA experts from university centers and private laboratories in different areas from Brazil discussed and agreed upon recommendations for the fourth edition of the Brazilian Consensus for Autoantibodies Screening in HEp-2 Cells. RESULTS AND CONCLUSION: The 4th ANA Consensus included three novel patterns into the existing algorithm (cytoplasmic Rods and Rings, nuclear Quasi-homogeneous, and CENP-F). Emphasis was given to the need of attention in describing the peculiar mixed pattern elicited by anti-DNA topoisomerase I (Scl-70) autoantibodies, comprising nuclear fine specked, nucleolar homogeneous pattern, NOR staining in metaphase plates, and cytoplasmic fine speckled patterns. The group also emphasized the need for continuous quality control in indirect immunofluorescence assays, the establishment of screening dilutions, as well as conjugate titration. An alert was made regarding the heterogeneity of commercial kits in defining patterns and the use of solid phase methodologies to determine the presence of autoantibodies.


Assuntos
Autoanticorpos/sangue , Autoanticorpos/isolamento & purificação , Linhagem Celular Tumoral/imunologia , Células Epiteliais/imunologia , Brasil , Células Epiteliais/classificação , Técnica Indireta de Fluorescência para Anticorpo , Humanos , Guias de Prática Clínica como Assunto
7.
Rev. bras. reumatol ; 54(1): 13-20, Jan-Feb/2014. tab, graf
Artigo em Português | LILACS | ID: lil-704281

RESUMO

Objetivo: Definir o título anormal e a diluição de triagem adequada para o teste de FAN (fator antinúcleo) por imunofluorescência indireta em células HEp-2 (FAN HEp-2). Métodos: Realizamos a pesquisa do FAN HEp-2 em amostras de soro de 126 indivíduos saudáveis. As amostras foram triadas na diluição de 1:80, e aquelas positivas diluídas até o título de 1:5120. O título anormal de FAN foi definido como aquele correspondente ao percentil 95 do teste nesta população. A sensibilidade dos diferentes títulos do FAN foi determinada em um grupo de 136 pacientes com diagnóstico de doença reumática autoimune, e a especificidade em um grupo de 118 pacientes com diagnóstico de outras doenças reumáticas. O valor de corte ótimo do teste foi determinado pelo estudo da curva ROC. Resultados: A frequência de FAN positivo em indivíduos saudáveis foi de 13,2%. Não houve diferença na frequência de resultados positivos de acordo com o gênero ou a idade. O título anormal do FAN foi definido como a diluição de 1:160. A diluição dos soros de 1:80 apresentou sensibilidade de 87,7% e especificidade de 67,8%, enquanto a diluição de 1:160 apresentou sensibilidade de 82% e especificidade de 73,7%. Pela análise da curva ROC, a diluição de 1:160 correspondeu ao valor de corte ótimo. Conclusão: O título anormal e o valor de corte ótimo do FAN HEp-2 na população avaliada foram de 1:160. A diluição de 1:160 é, portanto, a diluição de triagem ideal, com melhor especificidade, porém sem comprometimento significativo da sensibilidade diagnóstica do teste. .


Objective: To establish the abnormal title and the appropriate screening dilution for ANA (antinuclear antibodies) test by indirect immunofluorescence on HEp-2 cells (ANA HEp-2). Methods: An analysis of ANA Hep-2 in serum samples from 126 healthy individuals was performed. The samples were screened at a dilution of 1:80, and those positive were diluted to the title of 1:5120. The abnormal title of ANA was defined as that corresponding to the 95th percentile of the test in this population. The sensitivity of the different titles of antinuclear antibodies was determined in a group of 136 patients with a diagnosis of autoimmune rheumatic disease, and the specificity was determined in a group of 118 patients with other rheumatic diseases. The optimal cutoff value of the test was determined by ROC curve analysis. Results: The frequency of ANA positivity in healthy subjects was 13.2%. There was no difference in the frequency of positive results according to gender or age. The abnormal title of ANA was defined as the dilution of 1:160. The 1:80 dilution had sensitivity of 87.7% and specificity of 67.8%, while the 1:160 dilution had sensitivity of 82% and specificity of 73.7%. By ROC curve analysis, a dilution of 1:160 corresponded to the optimal cutoff value. Conclusion: The abnormal title and the optimal cutoff value of ANA HEp-2 in the population was 1:160. Therefore, the dilution of 1:160 is the optimal screening dilution, with better specificity but without significantly compromising the sensitivity of the diagnostic test. .


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anticorpos Antinucleares/sangue , Anticorpos Antinucleares/isolamento & purificação , Doenças Autoimunes/sangue , Doenças Autoimunes/diagnóstico , Doenças Reumáticas/sangue , Doenças Reumáticas/diagnóstico , Doenças Autoimunes/imunologia , Linhagem Celular Tumoral , Células Epiteliais/classificação , Células Epiteliais/imunologia , Técnica Indireta de Fluorescência para Anticorpo , Curva ROC , Doenças Reumáticas/imunologia
8.
Rev. bras. reumatol ; 54(1): 44-50, Jan-Feb/2014. graf
Artigo em Português | LILACS | ID: lil-704288

RESUMO

Objetivo: O IV Consenso Brasileiro para Pesquisa de Autoanticorpos em Células HEp-2 (FAN) realizado em Vitória (ES), no dia 18 de setembro de 2012, objetivou discutir estratégias e recomendações relacionadas ao procedimento técnico, à padronização e à interpretação dos resultados da pesquisa de autoanticorpos em células HEp-2. Métodos: Participaram do evento 23 pesquisadores e especialistas de Universidades e laboratórios brasileiros. Foram abordados diferentes tópicos, discutidos amplamente a fim de se estabelecer recomendações específicas. Resultados e conclusão: O IV Consenso integrou à árvore de decisão o padrão citoplasmático em Anéis e Bastões, o padrão nuclear pontilhado Quasi-homogêneo (QH) e o padrão misto CENP-F. Discutiu-se ainda a necessidade de atenção para a classificação do padrão misto relacionado à presença de anticorpos anti-DNA topoisomerase I (Scl70), compreendendo os componentes nuclear pontilhado fino, nucleolar homogêneo, NOR na placa metafásica e citoplasmático pontilhado fino. Foram sugeridas diretrizes para o controle de qualidade do teste, diluição de triagem e diluição de esgotamento, e foi emitido alerta quanto à necessidade de atenção em relação à heterogeneidade de substratos disponíveis no mercado e a utilização de metodologias automatizadas para detecção de autoanticorpos. .


Objective: The Fourth Brazilian Consensus for Autoantibodies Screening in HEp-2 Cells (ANA) was held in Vitória, Espírito Santo, and aimed to discuss strategies and recommendations about the technique, standardization, interpretation and quality control of the indirect immunofluorescence reaction on HEp-2 cells. Methods: Twenty three ANA experts from university centers and private laboratories in different areas from Brazil discussed and agreed upon recommendations for the fourth edition of the Brazilian Consensus for Autoantibodies Screening in HEp-2 Cells. Results and conclusion: The 4th ANA Consensus included three novel patterns into the existing algorithm (cytoplasmic Rods and Rings, nuclear Quasi-homogeneous, and CENP-F). Emphasis was given to the need of attention in describing the peculiar mixed pattern elicited by anti-DNA topoisomerase I (Scl-70) autoantibodies, comprising nuclear fine specked, nucleolar homogeneous pattern, NOR staining in metaphase plates, and cytoplasmic fine speckled patterns. The group also emphasized the need for continuous quality control in indirect immunofluorescence assays, the establishment of screening dilutions, as well as conjugate titration. An alert was made regarding the heterogeneity of commercial kits in defining patterns and the use of solid phase methodologies to determine the presence of autoantibodies. .


Assuntos
Humanos , Autoanticorpos/sangue , Autoanticorpos/isolamento & purificação , Linhagem Celular Tumoral/imunologia , Células Epiteliais/imunologia , Brasil , Células Epiteliais/classificação , Técnica Indireta de Fluorescência para Anticorpo , Guias de Prática Clínica como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...